Effect of connected system on gas pressure controllers’ stability
- Авторы: Sverbilov V.1
-
Учреждения:
- Центральный институт авиационного моторостроения им. П.И. Баранова, Москва
- Выпуск: Том 1, № 1 (2014)
- Страницы: 17-23
- Раздел: Статьи
- Дата публикации: 22.06.2014
- URL: https://dynvibro.ru/dynvibro/article/view/1649
- DOI: https://doi.org/10.18287/2409-4579-2014-1-1-17-23
- ID: 1649
Цитировать
Полный текст
Аннотация
In the paper the influence of dynamic performances of pipe systems connected to the control valve on system stability is studied through mathematical modeling and experimental work. Dynamic interaction between typical pressure control valves and up- and downstream pipelines is investigated. Stability criteria are derived in the form of requirements for input impedances of pipes connected. The best and the worse boundary conditions are deduced for each type of controllers. The best boundary conditions ensure stability even in a case of zero damping of the poppet. The worse boundary conditions determine maximum damping required to keep stability in any other system. To meet the requirements received, effective measures are suggested for each type of the control valve on the basis of special corrective devices (compensators) of the acoustic filter type. A scheme, parameters and location of the devices are determined by the type and parameters of the valve.
Ключевые слова
Об авторах
V. Y. Sverbilov
Центральный институт авиационного моторостроения им. П.И. Баранова, Москва
Автор, ответственный за переписку.
Email: v.sverbilov@mail.ru
Россия