Vibroacoustic loads reduction in pipe systems of gas distribution stations

Cover Page

Cite item

Full Text

Abstract

In the present paper the model of the pressure reducing valve with silencer is created in Matlab. The model is used for determining, how seated valve opens, outlet pressure and acoustic power level with downstream silencer fitted at outlet of it. The flow areas optimization of multi-stage silencer is completed. The impact of different design parameters on acoustic characteristics of the system is investigated by modeling and experiments. As a result of the paper the design of silencer, which reduces noise to 30 dBA, is created.

 

Key words: Pipeline system; gas distribution station; pressure regulator; noise; silencer

About the authors

A. A. Igolkin

Самарский государственный аэрокосмический университет имени академика С. П. Королёва

Author for correspondence.
Email: igolkin@pochta.ru
Russian Federation

References

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2015 Journal of Dynamics and Vibroacoustics


Journal of Dynamics and Vibroacoustics

ISSN 2409-4579 (Online)

Publisher and Founder: Samara National Research University, 34, Moskovskoye shosse, Samara, 443086, Russian Federation.

Extract from the register of registered media

Editor-in-chief:  Academician of the RAS
E. V. Shakhmatov 

4 issues per year.

Free price

Editorial address: room 324, 43, Gaya street, Samara, 443086

Address for correspondence: 34, Moskovskoye shosse, Samara, 443086, Russian Federation, Samara National Research University (room 324, building 14)

Phone: 8 (846) 267 47 66

e-mail: dynvibro@ssau.ru

www: https://dynvibro.ru

© Samara University

 

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies